99久久亚洲综合精品成人,人妻少妇久久中文字幕一区二区,国产嫖妓一区二区三区无码,国产精品夜色一区二区三区

AC source power & DC source power manufacturing factory

Calculating method of alarm current

As we all know, the capacity selection of AC power supply equipment is very important.choosing the right AC power supply is very important for production, manufacturing, testing and R&D!

excessive capacity selection will increase unnecessary property investment; too small capacity selection will affect the normal production, testing and R&D process and even lead to unusable.

therefore, mastering and understanding the calculation of alarm current will clearly know how to choose the capacity of AC power supply equipment. Suitable power supply equipment will make people feel like a tiger!

AC power supply is divided into single-phase power supply and three-phase power supply according to the different output power.therefore, the calculation method of alarm current can also be divided into two kinds: single-phase power supply and three-phase power supply.
the following are introduced separately:

One:Single-phase power supply
Output 0-300V: divided into low and high gear.the alarm current of low-voltage gear is 120 V, and that of high-voltage gear is 240V. capacity (VA)/gear voltage (V)=gear alarm current (A).

Take 5KVA power supply as an example: 5000VA (capacity)/120V (low grade)≈42A; 5000VA/240V (high grade)≈21A.so we get the alarm current: the output of 5KVA power supply is in the range of 0 -150V, the maximum alarm (limit) current is 42A; the output of 5KVA power supply is in the range of 0 -300V, and the maximum alarm (limit) current is 21A.

Output 0-600V, low-grade 240V, high-grade 480V, the same method to get the alarm current of 21/10.5A.
The simple method is that we only need to calculate the low-grade or high-grade alarm current. Another kind of alarm current can be obtained immediately according to the low-grade alarm current = 2 times the high-grade alarm current

Two: Three-phase power supply
The alarm current is a single-phase alarm current, so the three-phase power supply needs capacity/3 to get the single-phase capacity, and then according to the calculation method of the alarm current of the single-phase power supply, the alarm current of the three-phase power supply can be obtained.

Take three-phase 15KVA power supply as an example: 15KVA/3 = 5KVA, 5000VA/120V≈42A (low-grade alarm current), 42A/2 ≈21A (high-grade alarm current).therefore, the alarm current of three-phase 15KVA power supply is 42/21A.

It is not difficult to find that the calculation of alarm current focuses on the unit of capacity is VA, the unit of voltage is V, and the unit of alarm current is A. Therefore, if the known unit of capacity is KVA, the unit of KVA should be converted to VA when calculating the alarm current. 1KVA is 1000VA.
Recommend Products
Online service
Service Hotline
86-769-89616802
86-13602353727

ADMIRE POWER
久久狼人大香伊蕉国产| 亚洲中文久久精品无码99| 国产精品视频露脸| 亚洲精品有码在线观看| 久久综合精品成人一本| 亚洲αv久久久噜噜噜噜噜| 上海少妇高潮狂叫喷水了| 亚洲女初尝黑人巨| 老司机亚洲精品影院无码| 国产老熟女狂叫对白| 久久精品国产精油按摩| 夜夜爱夜鲁夜鲁很鲁| 国内外精品成人免费视频| 午夜理论无码片在线观看免费| 国产免费无码一区二区视频 | 国产精品爽爽久久久久久竹菊| 亚洲成av人无码中文字幕| 国产三级精品三级在线观看| 欧洲美女黑人粗性暴交视频| 国产精品亚洲精品久久精品| 欧美又粗又长又爽做受| 国产一区二区三区高清在线观看 | 日韩精品一卡二卡二卡四卡乱码| 日本人妻中文字幕乱码系列| 成人做爰视频www网站小优视频| 国产麻豆精品一区| 亚洲性人人天天夜夜摸18禁止| 国产精品日本亚洲777| 日本护士╳╳╳hd少妇| 青青青伊人色综合久久| 久女女热精品视频在线观看| 亚洲综合另类小说色区大陆| 香蕉久久av一区二区三区app| 蜜桃传媒av免费观看麻豆| 99久久久国产精品无码免费| 亚洲中文字幕a∨在线| 性高朝久久久久久久久久| 换脸国产av一区二区三区| 日韩夜夜高潮夜夜爽无码| 成年男人午夜片| 国产欧美va欧美va香蕉在线|